Darshil Automation Control and Service (DACS) is a well-known Star Delta Starter Control Panel Producer located in Changodar, Ahmedabad providing heavy-duty motor starting and protecting panels to the states in India. Our Star-Delta starter panels use three-phase squirrel-cage induction motors above 7.5 HP which reduces high initial incoming current to one-third of DOL (Direct-On-Line) starting current.

The reason for doing so is that this avoids dips in the voltage in the plant busbar and prevents damage of the motor windings and mechanical couplings because of the torque impact.

The functioning of the Automatic Star-Delta Starter Panel

This happens when a high-capacity industrial motor starts directly at full line voltage and consumes 6 to 8 times more electricity than it needs. Our Automatic Star-Delta Control Panels solve this issue in 2 consequent processes.

  • Star Connection Process: The main and star contactors are turned on to establish the connection of the stator windings of the motor to the Star connection.
  • Timer-Controlled Delta Transition: After attaining a motor speed of 80% to 85% of its rated synchronous speed, the electronic star-delta timer switches off the star contactor while switching on the delta contactor after a safe interval of 50 to 100ms.
ParameterStandard Specification
Motor Power Rating7.5 HP to 150 HP (5.5 kW to 110 kW)
Rated Operational Voltage415V AC, 3-Phase, 50 Hz (±10% variation)
Rated Insulation Voltage660V / 1000V AC as per IS/IEC 60947
Control Circuit Voltage230V AC / 110V AC / 24V DC (with control transformer)
Enclosure Construction14 / 16 SWG CRCA Sheet Steel, CNC-fabricated
Surface Treatment7-Tank / 9-Tank Phosphating with RAL 7032 / 7035 Powder Coating
Degree of ProtectionIP54 (Indoor) / IP55 & IP65 (Outdoor Weatherproof with Canopy)
Busbar SystemHigh-conductivity Electrolytic Grade Copper or Aluminium with heat-shrink PVC sleeves
Switchgear BrandsSchneider Electric, Siemens, L&T, ABB (as per client BOM)
Protection RelaysBi-metallic / Electronic Thermal Overload Relay, Single-Phasing & Phase-Reversal Preventer, Short-Circuit MCCB/MPCB
Metering & IndicationDigital VAF Meter, LED Phase Indications (R-Y-B), ON/OFF/TRIP Lamps, Start/Stop Push Buttons, Auto/Manual Selector Switch
  • Interlocking: Utilization of mechanical interlock blocks along with electrical auxiliary contacts ensures that both star and delta contactors are not closed at the same time, thus preventing any phase-to-phase short circuits.
  • Custom Multi-Feeder Design: The starter boxes can be standalone in-wall or floor-mounted or can be made into compartments in one’s main MCC Panel.
  • Ready for Integration with BMS & PLC: The panels are equipped with NO/NC contacts and also remote Start/Stop terminals, facilitating integration into PLC systems.
  • Testing of all Panels: All panels undergo insulation resistance testing (megger), dielectric testing, and functional testing prior to dispatch from Ahmedabad.
FeatureDOL Starter PanelStar-Delta Starter PanelVFD Control Panel
Typical Motor SizeUp to 7.5 HP7.5 HP to 150 HP1 HP to 500+ HP
Starting Current600%–800% of FLC200%–260% of FLC100%–150% of FLC
Speed ControlFixed SpeedFixed SpeedVariable Speed (0–50 Hz)
Initial CostLowestModerate & Cost-EffectiveHigher
Best Use CaseSmall pumps & fansConstant-speed heavy motorsVariable flow/torque loads
  • Water Treatment System: Centrifugal pumps for raw water, high-pressure pumps for reverse osmosis, and boosting stations in municipalities.
  • HVAC and Utilities: Air compressors, cooling tower fans, air-moving fans, and chilled water pumps for circulation.
  • Manufacturing and Processing: Crushers, mix mills, and agitatorators.

1. What information do we need to get a quote for a Star-Delta Starter Panel?
Please provide the KW/HP ratings of your motor, its full load current (FLC) requirement, whether the motor is installed indoors or outdoors, the brand of switchgear you prefer, e.g. Siemens, Schneider, L&T, ABB and whether there is need for remote start/stop signal through PLC.

2. Can a Star-Delta starter be used for a 3-lead motor?
No, Star-Delta starter requires connection of all 6 stator winding terminals i.e. U1, V1, W1 and U2, V2, W2 to the motor terminal box.